Click here to return to the home page.
Image of a road.
Who's Online Now
2 members (+8Rich, DaveK), 326 guests, and 39 robots.
Key: Admin, Global Mod, Mod
Top Posters(30 Days)
+8Rich 96
Luddite 54
Newest Members
phenompilot52, Orjan, John Courtney, vince Indiana US, Garage Andreas
9,635 Registered Users
Newest Topics
small hose from air cleaner - 1989
by Carbuilder - 12/09/26 04:50 PM
New member in NYC
by SEG - 12/09/26 04:13 PM
Door card removal ?
by Pittsartist - 12/09/26 11:35 AM
New to me plus 4
by SailingTom2 - 12/09/26 06:24 AM
Hot Bonnet
by Carbuilder - 11/09/26 11:21 PM
morgan supersport 357 miles
by Nick_H - 09/09/26 09:13 PM
M3W Treffen 2027
by Laurens - 09/09/26 08:12 PM
Latest Photos
New to me 95 plus 4 daily driver
New to me 95 plus 4 daily driver
by SailingTom2, September 12
1989 Morgan Plus 4 in Ontario, Canada
1989 Morgan Plus 4 in Ontario, Canada
by Carbuilder, September 5
First anniversary of Plus 4
First anniversary of Plus 4
by Strathaven, September 5
Wales
Wales
by Joske Vermeule, September 1
Engine/Gearbox Separator CX Models
Engine/Gearbox Separator CX Models
by number thirteen, August 30
Forum Statistics
Forums39
Topics49,904
Posts838,085
Members9,635
Most Online1,063
Jun 14th, 2026
Today's Birthdays
dogmanjack, Frabro
Previous Thread
Next Thread
Print Thread
Page 1 of 4 1 2 3 4
#555326 22/01/19 01:30 PM
Joined: Nov 2018
Posts: 6,676
Likes: 441
TBM Offline OP
Talk Morgan Sage
OP Offline
Talk Morgan Sage
Joined: Nov 2018
Posts: 6,676
Likes: 441
And on to my next issue smile

I have the round Smiths Heater in the passenger footwell and although she gets a little warm, she doesn't get hot. The previous owner had a tap installed, so it must have got 'too warm' at some point in the past.

At the weekend I replaced the hoses, removed the tap and flushed the heater matrix in both directions. However she still doesn't seem to get warm.

I have one hose that goes from a 'take off' on the the water pump and into the heater matrix and a second hose that goes from the matrix to the inlet manifold.

When the engine runs, the hose from the heater matrix to manifold gets warm, whereas the hose from the water pump to heater remains cold. Personally I would have thought the opposite - the water should flow from the water pump, to the heater matrix and then back in through the manifold so the hoses should either be the same temperature, or the pump to matrix hose should be slightly warmer.

Any thoughts?

Both hoses are new. The matrix is clear and water is definitely flowing out of the water pump at pressure when running and the car maintains temperature well.


"Y mae dafad ddu ym mhob praidd"
1972 4/4, 1981 MGBGT, 1984 FLHT1340, 1980 XLH1000, 1990 ZX10
TBM #555327 22/01/19 02:27 PM
Joined: Aug 2008
Posts: 2,515
Likes: 1
Talk Morgan Expert
Offline
Talk Morgan Expert
Joined: Aug 2008
Posts: 2,515
Likes: 1
Manifold to heater then return to the water pump is the correct direction. It sounds like you have an air-lock. I'd loosen the clip on the heater return hose and gently pull it away when the engine's just started to see if any air comes out.


1972 4/4 2 Seater
Joined: Nov 2018
Posts: 6,676
Likes: 441
TBM Offline OP
Talk Morgan Sage
OP Offline
Talk Morgan Sage
Joined: Nov 2018
Posts: 6,676
Likes: 441
Originally Posted By tmg513
Manifold to heater then return to the water pump is the correct direction. It sounds like you have an air-lock.


Ah, opposite to the way I thought and will explain why that hose gets hot first. Thank you.


Originally Posted By tmg513
I'd loosen the clip on the heater return hose and gently pull it away when the engine's just started to see if any air comes out.


I did this - got showered in fluid- there was definitely water coming out of the matrix. I'll have a crack again at the weekend and see if I can get any air out. Is there a preferred 'in and out' for the matrix? Currently the hose from manifold enters the matrix on the passenger left/passenger side and exits back to water pump on the right/drivers side.

If I was going to fit a tap, am I right to assume it should be in the hose going from manifold to matrix, rather than in the hose from matrix to pump (as fitted by Allon White).


"Y mae dafad ddu ym mhob praidd"
1972 4/4, 1981 MGBGT, 1984 FLHT1340, 1980 XLH1000, 1990 ZX10
TBM #555331 22/01/19 02:41 PM
Joined: May 2014
Posts: 5,442
Likes: 133
Black Rat
Charter Member
Offline
Black Rat
Charter Member
Joined: May 2014
Posts: 5,442
Likes: 133
Try removing both hoses and filling the heater manually


Keith
2013 narrow bodied + 4 Ruby.
TBM #555352 22/01/19 04:33 PM
Joined: Nov 2015
Posts: 8,701
Likes: 501
Just barreling along
Needs to Get Out More!
Offline
Just barreling along
Needs to Get Out More!
Joined: Nov 2015
Posts: 8,701
Likes: 501
If you feed the hot supply in to the top of a matrix & the return cooler water out of the lower level, you will aid circulation by the thermo-syphonic effect


Jon M
TBM #555354 22/01/19 04:42 PM
Joined: Feb 2013
Posts: 519
Likes: 60
B
Talk Morgan Regular
Offline
Talk Morgan Regular
B
Joined: Feb 2013
Posts: 519
Likes: 60
make sure a thermostat is fitted.

David Byrne

Joined: Nov 2018
Posts: 6,676
Likes: 441
TBM Offline OP
Talk Morgan Sage
OP Offline
Talk Morgan Sage
Joined: Nov 2018
Posts: 6,676
Likes: 441
Originally Posted By CooperMan
If you feed the hot supply in to the top of a matrix & the return cooler water out of the lower level, you will aid circulation by the thermo-syphonic effect


Unfortunately Inlet and Outlet are exactly the same level.


"Y mae dafad ddu ym mhob praidd"
1972 4/4, 1981 MGBGT, 1984 FLHT1340, 1980 XLH1000, 1990 ZX10
TBM #555387 22/01/19 07:59 PM
Joined: Aug 2008
Posts: 2,515
Likes: 1
Talk Morgan Expert
Offline
Talk Morgan Expert
Joined: Aug 2008
Posts: 2,515
Likes: 1
You could try eliminating the matrix by joining the two hoses together and seeing whether the whole length of the joined hose heats up. That should give you a better idea exactly where the problem is.


1972 4/4 2 Seater
Joined: Nov 2018
Posts: 6,676
Likes: 441
TBM Offline OP
Talk Morgan Sage
OP Offline
Talk Morgan Sage
Joined: Nov 2018
Posts: 6,676
Likes: 441
Originally Posted By tmg513
You could try eliminating the matrix by joining the two hoses together and seeing whether the whole length of the joined hose heats up. That should give you a better idea exactly where the problem is.


Good plan


"Y mae dafad ddu ym mhob praidd"
1972 4/4, 1981 MGBGT, 1984 FLHT1340, 1980 XLH1000, 1990 ZX10
TBM #555466 23/01/19 09:27 AM
Joined: Nov 2015
Posts: 8,701
Likes: 501
Just barreling along
Needs to Get Out More!
Offline
Just barreling along
Needs to Get Out More!
Joined: Nov 2015
Posts: 8,701
Likes: 501
Originally Posted By TBM
Originally Posted By CooperMan
If you feed the hot supply in to the top of a matrix & the return cooler water out of the lower level, you will aid circulation by the thermo-syphonic effect


Unfortunately Inlet and Outlet are exactly the same level.


Oh dear, not well designed, this makes you totally reliant on the efficiency of the water pump and the frictional losses of the hoses and matrix core, you may have a partial air lock in the heater - try a bit of a power flush with a hosepipe via the feed pipework


Jon M
Page 1 of 4 1 2 3 4

Moderated by  TalkMorgan 

Link Copied to Clipboard
Powered by UBB.threads™ PHP Forum Software 7.7.5